Set Up: MVI56E-MNET Modbus TCP/IP Communications Interface Module

Set Up: MVI56E-MNET Modbus TCP/IP Communications Interface Module

The ProSoft Technology MVI56E Modbus TCP/IP Communication Module is designed to allow ControlLogix processors to interface easily with other Modbus TCP/IP protocol-compatible devices.

Compatible devices include not only Modicon processors (which support the Modbus TCP/IP protocol) but also a wide assortment of other clients and server devices.
Features and Benefits

The MVI56E-MNET module is a single slot solution that provides a powerful connection between Rockwell Automation’s ControlLogix processor and Modbus TCP/IP network applications.

The TCP/IP Modbus network applications include those networks hosted by Modicon Quantum processors, networks controlled by operator interface software packages, and the growing number of manufactured devices that support this protocol. The MVI56E-MNET module acts as an input/output module between the Modbus TCP/IP network and the Rockwell Automation backplane. The data transfer from the processor is asynchronous from the actions on the Modbus TCP/IP network. A 5000-word register space in the module exchanges data between the processor and the Modbus TCP/IP network.

Support for the storage and transfer of up to 5000 registers to/from the ControlLogix processor using the block transfer or side-connect interface
User-definable module memory usage
10/100 MB Ethernet compatible interface
Configurable parameters for the client including a minimum response delay of 0 to 65535 mSec and floating point support

For questions, please visit http://www.prosoft-technology.com

You may also like

Demo: ProSoft Wireless Designer and IH Browser
15:53
Planning an industrial wireless network? You'll want to watch this ...
Webinar: The Future of Remote Networking
33:41
We’re setting up remote data transfers among three continents – you’ll ...
Set Up: PROFIBUS DPV1 Master/Slave Module for ControlLogix®
28:40
In this training video, we focus on setting up the new ILX56-PBM ...
Set Up: For AB Remote I/O to EtherNet/IP Flex I/O scanner
17:17
This video walks you through the process to setup ProSoft's ...
Groundbreaking Security and Safety feature for Remote Access
8:14
In this video, we’ll go over the process to enable and use a new ...
Set Up:  SMS Messaging with a Modicon M340 PLC
11:09
In this follow-up training video about ProSoft Technology’s ICX35-HWC ...
Set Up: For AB Remote I/O™ to EtherNet/IP™ drive migration gateway
18:21
This video teaches you how to setup ProSoft's AN-X2-AB-DHRIO gateway ...
Set Up: Upload and Download PLC programs from an EtherNet/IP™ PC to a DF1 PLC
7:29
Since Rockwell Automation® discontinued the 1761-NET-ENI, you may be ...

Page 1 of 10